ADD: NO.403 QinXiYang Industry Area, Fuan, Fujian. China
TEL: +86-593-6688936
FAX: +86-593-6688956
E-Mail: sales@wernerpower.com
The DC power is composed of permanent magnetic alternator with special parameter and big power rectifier module, equipped with battery output characteristic, meet the standards of power use of communicate base station. There is faults detection function and stable automatic stop protection device to insure the safety of the DC power system, which is fit for battery charging property requirement and can be selected to charging battery. Our DC power system could be customized according to requirements of customer in special field.
Technical Data
This DC power adopt high efficiency permanent magnetic brushless alternator, together with intelligent electronic module, with intelligent performance, flexible and convenient small volume, high efficiency and energy saving to instead of traditional DC generator which needs to transform AC to DC.Good dynamic performance and output fast transient response, high stability, provide quality DC electric energy for Telecom,car charging,truck power and so on. The PMG built with axial fan with can suppply enough ventilation to insure magnets working long time without demagnetization.It highly enhence the stability of the alternator. All electronic products are glue filled to anti-vibration,moisture-proof,anti-corrossion,working tempeture -40℃-45℃,can work in hostile environment. |
|||||
Advantages: | |||||
● Strong loading ability, which can drive compressor, air condition and so on | |||||
● Supply long continue running hours | |||||
●Medium frequency multiphase rectified, high quality and low output ripple factor | |||||
●Super compact and light for special application | |||||
●Anti-corrossion,moistureproof,anti-vibration,salt fog proof,working tempeture -40℃-45℃ ,suitable for hostile environment | |||||
Genset | |||||
Model Name | W30A | W50A | W60A | W80A | W90A |
Rated AC output | 3KW | 4KW | 5KW | 8KW | 10KW |
DC voltage | 48V | ||||
Voltage range | 45V-60V | ||||
DC current | 12A | 83A | 135A | 165A | 200A |
output waveform | DC output | ||||
Fuel Tank(L) | 12 | 12 | 17 | 24 | 30 |
Dimension(mm) | 500×470×470mm | 500×470×470mm | 600×550×550mm | 620×590×620mm | 630×580×770mm |
Net weight | 38KG | 40KG | 65KG | 73KG | 117KG |
ENGINE | |||||
Engine | 170F | 170F-2T | 190F-T | 192F-2T | 2V80F |
Engine Type | 4-stroke, OHV, single cylinder, cylinder inclined, air cooled,petrol | 2 cylinders | |||
Displacement | 212ml | 223ml | 420ml | 459ml | 744ml |
Compression | 9:01 | 9:01 | 9:01 | 9:01 | 8.5:1 |
Rated rev | 3200r/min | 3600r/min | 3200r/min | 3200r/min | 3200r/min |
Ignition system | T.C.I | ||||
Start system | Recoil hand-operated, electric system | ||||
Engine Max output | 4KW | 4.4KW | 8.8KW | 11KW | 16KW |
Fuel comsumption | ≤370g/kw.h | ≤370g/kw.h | ≤370g/kw.h | ≤370g/kw.h | ≤370g/kw.h |
Lube Oil capacity | 0.6L | 0.6L | 1.1L | 1.1L | 1.4L |
Alternator | |||||
Alternator | PMG type DC alternator | ||||
Model Name | F30AD | F50AD | F60AD | F80AD | F90AD |
Rated AC output | 3KW | 4KW | 5KW | 8KW | 10KW |
DC voltage | 48V | ||||
Transient Max current | 1.7 times of rated power | ||||
output efficiency | >90% |